Surface Science

Showing 49–60 of 60 results


    • Industry-leading low drift (0.1 μRIU/min)
    • Extremely low noise (0.05 μRIU rms)
    • High sample capacity (up to 768 samples per run)
    • High-quality, publication-ready data
    • The most sensitive, flexible and affordable 2-channel system available
    • The best performance-to-cost ratio for individual labs
    • A proven SPR leader since 1997
    • Faster baseline stability — the Reichert2SPR System stabilizes 2x-3x faster than the competition, due to our streamlined fluidics

     

     

  • Reichert and the PAR Potentiostat

    • Maximum current up to 1A with additional booster options ranging from 2A-20A
    • 2µs time base for faster data acquisition and scan rates
    • Additional analog filter selections on current and voltage channels for superior signal/noise measurements

     

    • Maximum current up to 1A with additional booster options ranging from 2A-20A
    • 2µs time base for faster data acquisition and scan rates
    • Additional analog filter selections on current and voltage channels for superior signal/noise measurements

     

    • Features low volume with extremely fast rise and decay times on both channels
    • It features very small dead volumes
    • Uses standard PEEK™ HPLC/FPLC fittings
    • Compatible with tubing sizes down to 0.0025″ Inner Diameter (65 micrometers)

     

    • Surface plasmon field enhanced fluorescence spectroscopy
    • Extremely sensitive and effective tool for detecting and quantifying biomolecular binding
    • Left and right fluid path imaged after binding FITC labeled antibody to sensor slide surface.
    • features a quartz window in each of the fluidic pathways to enable SPR experiments combined with Photochemistry/ Fluorescence.

     

  • Market leading experience in FluidFM for AFM

    • Highly accurate pressure, force, and position control with optical sample access
    • Different FluidFM® probes: hollow cantilevers designed for specific applications
    • Pioneering research within reach

     

  • The best solution for automated force mapping

    • Straightforward experimental workflow: only a few steps from sample mounting to results
    • One-click cantilever calibration: automatic cantilever deflection sensitivity and spring constant (Sader method) measurement
    • Real-time data analysis: Young’s modulus, adhesion, and indentation are calculated and displayed during the measurement
    • Facilitates measurements on demanding samples: experimental workflow repositions the sample for every measurement area

     

  • AFM systems fully tailored to your specifications

    • Meeting to understan your requirements
    • Nansosurf outlines solution
    • joint discussion of solution,
    • adaptation solution concept
    • order based on concept

     

    • Cylindrical mirror analyzer (CMA)
    • Coaxial 25 kV field emission electron gun
    • Scintillation secondary electron detector
    • High energy resolution module
    • 5 axis automated sample stage
    • 5 kV floating column Ar+ ion gun
    • SmartSoft-Auger instrument control software
    • MultiPak data reduction software
    • Acoustic Enclosure
    • Ion pumped main chamber

     

    • TRIFT mass analyzer
    • 30 kV LMIG with Bi, Au, or Ga emitter
    • Dual beam charge neutralization
    • 5 axis sample stage
    • In-situ optical viewing
    • Secondary electron detector
    • WinCadence instrument control and data reduction software package
    • Analysis chamber with four primary ion gun ports
    • 350 l/s turbo molecular pump
    • Integrated bakeout facilities
    • MS/MS ready spectromoter

     

    • To Flow Cell – Headless Nut 10-32 for 1/6″ O.D. Tubing
    • Total Volume: 25µL (Volume occupied by Counter Electrode 7uL) Wetted Materials
    • Tubing – PEEK™
    • Flow Cell – Acetal Copolymer (Delrin)
    • Counter Electrode – Platinum
    • Working Electrode – Gold SPR Sensor Slide
    • Reference Electrode – Ceramic Porous Junction

     

    • Provides easy adaptability to MALDI mass spectrometry
    • Important in ligand fishing experiments
    • Sensor chip is not compromised

     

     